PP000xA Hi-Z+ Probes | |||||
Model | Bandwidth | Input Voltage | Input Impedance | Tip Type | |
PP0001A | 1 GHz | 300 V CAT II | 10 MΩ // 4.0 pF | 5mm tip | |
PP0002A | 800 MHz | 1200 V CAT II | 40 MΩ // 2.0 pF | 5mm tip | |
PP0003A | 1 GHz | 30 V CAT II | 10 MΩ // 4.0 pF | MMCX Connector |
General-Purpose Passive Probes | |||||
Model | Bandwidth | Attenuation Ratio | Input Impedance① | Compensation Range② | Notes |
N2840A | 50 MHz | 10:1 | 10 MΩ // 11 pF | 5 - 30 pF | |
10074D | 150 MHz | 10:1 | 10 MΩ // 15 pF | 9 - 17 pF | |
N2841A | 150 MHz | 10:1 | 10 MΩ // 11 pF | 5 - 30 pF | Recommended for InfiniiVision 2000 X-Series |
N2871A | 200 MHz | 10:1 | 10 MΩ // 9.5 pF | 10 - 25 pF | Optimized for fine-pitch probing |
N2842A | 300 MHz | 10:1 | 10 MΩ // 11 pF | 5 - 30 pF | Recommended for InfiniiVision 2000 X-Series |
N2853A | 350 MHz | 10:1 | 10 MΩ // 11 pF | 5 - 30 pF | |
N2872A | 350 MHz | 10:1 | 10 MΩ // 9.5 pF | 10 -25 pF | Optimized for fine-pitch probing |
N7007A | 400 MHz | 10:1 | 10 MΩ // 16 pF | 6 - 18 pF | Extreme temperature probing (-40 to +85°C), 2 meter cable |
N2843A | 500 MHz | 10:1 | 10 MΩ // 11 pF | 5 - 30 pF | Recommended for InfiniiVision 3000 X-Series |
10073D | 500 MHz | 10:1 | 2.2 MΩ // 12 pF | 6 - 15 pF | |
N2873A | 500 MHz | 10:1 | 10 MΩ // 9.5 pF | 10-25 pF | Fine-pitch, recommended for Infiniium EXR/MXR/S-Series |
N2875A | 500 MHz | 20:1 | 20 MΩ // 5.6 pF | 7 - 20 pF | Optimized for fine-pitch, low-capacitive probing |
N2894A | 700 MHz | 10:1 | 10 MΩ // 9.5 pF | 10 - 25 pF | Fine-pitch, recommended for InfiniiVision 4000/6000 X-Series |
PP0002A | 800 MHz | variable | 40 MΩ // 2.0 pF | N/A | 5 mm tip, 1200 V CAT II, requires PP0004A (AutoProbe 1) |
PP0001A | 1 GHz | variable | 10 MΩ // 4.0 pF | N/A | 5 mm tip, 300 V CAT II, requires PP0004A (AutoProbe 1) |
PP0003A | 1 GHz | variable | 10 MΩ // 4.0 pF | N/A | MMCX connector, 30 V CAT II, requires PP0004A (AutoProbe 1) |
High-Sensitivity 1:1 Passive Probes | |||||
Model | Bandwidth | Attenuation Ratio | Input Impedance① | Compensation Range | Notes |
10070D | 20 MHz | 1:1 | 1 MΩ // 70 pF + | N/A | Recommended for low-voltage measurements |
N2870A | 35 MHz | 1:1 | 1 MΩ // 39 pF + | N/A | Recommended for low-voltage measurements |
Switchable Passive Probes (1:1 // 10:1) | |||||
Model | Bandwidth | Attenuation Ratio | Input Impedance①,③ | Compensation Range② | Notes |
N2142A | 6 MHz | 1:1 | 1 MΩ // 100 pF + | N/A | Low-cost 2-pack, recommended for InfiniiVision EDUX1000 X-Series |
70 MHz | 10:1 | 10 MΩ // 15 pF + | 15 - 30 pF | ||
N2140A | 6 MHz | 1:1 | 1 MΩ // 100 pF + | N/A | Low-cost 2-pack, recommended for InfiniiVision EDUX1000 X-Series |
200 MHz | 10:1 | 10 MΩ // 15 pF + | 15 - 30 pF | ||
N2889A | 10 MHz | 1:1 | 1 MΩ // 60 pF + | N/A | The most general-purpose passive probe |
350 MHz | 10:1 | 10 MΩ // 11 pF + | 10 - 35 pF | ||
High-voltage Passive Probe (100:1) | |||||
Model | Bandwidth | Attenuation Ratio | Input Impedance① | Compensation Range② | Notes |
10076C | 500 MHz | 100:1 | 66.7 MΩ // 3 pF + | 6 - 18 pF | High-voltage, low capacitive probing |
High-frequency/Low-Z Passive Probes (50-Ω terminated) | |||||
Model | Bandwidth | Attenuation Ratio | Input Impedance④ | Compensation Range | Notes |
N2874A | 1.5 GHz | 10:1 | 500 Ω // 1.8 pF + | N/A | Low-cost, high-frequency probing at the cost of resistive loading |
N2876A | 1.5 GHz | 100:1 | 5 kΩ // 2.2 pF + | N/A | Low-cost, high-frequency probing at the cost of resistive loading |
TDR/TDT Probe | |||||
Model | Bandwidth | Type | Input Impedance | Tip Spacing Compatible TDR/TDT Modules |
Notes |
N1021B | 18 GHz | Differential | 100 Ω | variable between 0.5mm-2.54mm DCA-X N1055A & 54754A |
Designed for TDR applications, but also suitable as high bandwidth, passive probe for non-TDR applications |
1. Input impedance when terminated into oscilloscopes with 1-MΩ input terminations. For higher-bandwidth Infiniium oscilloscopes with 50-Ω input terminations only, the E2697A high impedance adapter can be purchased (includes 10073D 500-MHz passive probe) to provide a 1-MΩ input termination. 2. For proper probe compensation (flatness), the oscil loscope’s input capacitance must be within the specified compensation range of the probe. 3. Capacitance at the probe tip of 1:1 probes is the specified probe capacitance plus the capacitance of the oscilloscope when terminated into 1-MΩ. 4. Input impedance when terminated into oscilloscopes with 50-Ω input terminations. These probes are not compatible with Keysight’s InfiniiVision 1000 and 2000 X-Series oscilloscopes. |
High-Frequency Differential Active Probes < 10 GHz | ||||||||
Model | Bandwidth | Input Range | Probe Offset | Diff Input Impedance | Attenuation Ratio | Prob-to-scope Interface | Power Source | Oscilloscope Termination |
N2750A | 1.5 GHz | ±5 V | ±15 V | 100 kΩ/0.7 pF | 2:1/10:1① | AutoProbe1 | Oscilloscope | 50 Ω |
N2751A | 3.5 GHz | ±5 V | ±15 V | 100 kΩ/0.7 pF | 2:1/10:1① | AutoProbe1 | Oscilloscope | 50 Ω |
N2752A | 6.0 GHz | ±5 V | ±15 V | 100 kΩ/0.7 pF | 2:1/10:1① | AutoProbe1 | Oscilloscope | 50 Ω |
1130B② | 1.5 GHz | ±2.5 V | ±12 V | 50 kΩ/0.27 pF | 10:1 | AutoProbe1 | Oscilloscope | 50 Ω |
1131B② | 3.5 GHz | ±2.5 V | ±12 V | 50 kΩ/0.27 pF | 10:1 | AutoProbe1 | Oscilloscope | 50 Ω |
1132B② | 6.0 GHz | ±2.5 V | ±12 V | 50 kΩ/0.27 pF | 10:1 | AutoProbe1 | Oscilloscope | 50 Ω |
1134B② | 7.0 GHz | ±2.5 V | ±12 V | 50 kΩ/0.27 pF | 10:1 | AutoProbe1 | Oscilloscope | 50 Ω |
N2830A②,③ | 4 GHz | ±2.5 V | ±16 V | 100 kΩ/0.32 pF | 5:1/10:1① | AutoProbe1 | Oscilloscope | 50 Ω |
N2831A②,③ | 8 GHz | ±2.5 V | ±16 V | 100 kΩ/0.32 pF | 5:1/10:1① | AutoProbe1 | Oscilloscope | 50 Ω |
N7000A② | 8 GHz | ±2.5 V | ±16 V | 100 kΩ/0.32 pF | 5:1/10:1① | AutoProbe2 | Oscilloscope | 50 Ω |
①. Auto-selected based on V/division setting. ②. Requires differential probe head sold separately. ③. Not compatible with InfiniiVision X-Series oscilloscopes, but is compatible with the Infiniium UXR (1 mm & 1.85 mm models) with the cascaded use of the N5442A and N2852A adapters |
Oscilloscope Compatibility for High-Frequency Differential Active Probes (<10 GHz) | ||
Probe-to-scope Interface | Oscilloscope Termination | Compatible Oscilloscopes |
BNC | 50 Ω | • InfiniiVision 3000A, 3000T, 4000, and 6000 X-Series • Infiniium EXR, MXR, S-Series, 9000 Series • Any vendor’s oscilloscope with a BNC input connection and a 50 Ω input impedance termination |
AutoProbe1 | 50 Ω | • InfiniiVision 3000A, 3000T, 4000, and 6000 X-Series (except N2830A and N2831A) • Infiniium EXR, MXR, S-Series, 9000, and 90000A Series • Infiniium UXR (3.5 mm models), V, Z, Q, and 90000X Series with the use of the N5442A adapter |
AutoProbe2 | 50 Ω | • Infiniium UXR (3.5 mm models), V, Z, Q, and 90000X Series |
AutoProbe Interface Keysight’s AutoProbe interface provides the following: • DC voltage to power active probe circuitry • Automatic detection of probe attenuation • Automatic control of selectable probe attenuation on some probes • Probe DC offset on many probes |
High-Frequency Differential Active Probes ≥ 10 GHz | |||||||||
Model | Bandwidth | Impedance Profile① | Diff Input Impedance | Probe Noise② | Probe-to-Scope Interface | InfiniiMode③ | Input Range | Probe Offset | Attenuation Range④ |
MX0032A | 52 GHz (B-T 40 GHz) | RCRC | 100 kΩ/ 0.32 pF | 27.1 nV/ rt(Hz) | AutoProbe3 | No | ±1 V | ±12 V | 4.4:1/ 8.7:1 |
MX0031A | 52 GHz | RCRC | 100 kΩ/ 0.32 pF | 27.1 nV/ rt(Hz) | AutoProbe3 | No | ±1 V | ±12 V | 4.4:1/ 8.7:1 |
MX0030A | 42 GHz | RCRC | 100 kΩ/ 0.32 pF | 27.1 nV/ rt(Hz) | AutoProbe3 | No | ±1 V | ±12 V | 4.4:1/ 8.7:1 |
N2803A | 30 GHz | RCRC | 100 kΩ /0.32 pF | 23.9 nV/rt(Hz) | AutoProbe2 | No | ±1.25 V | ±16 V | 6:1 |
MX0025A | 25 GHz | RC | 50 kΩ/0.17 pF | 25.0 nV/rt(Hz) | AutoProbe2 | Yes | ±2.5 V | ±16 V | 1:1/4:1/8:1 |
MX0023A | 25 GHz | RC | 50 kΩ/0.17 pF | 25.0 nV/rt(Hz) | AutoProbe2 | No | ±1.25 V | ±16 V | 1:1/4:1 |
N2802A | 25 GHz | RCRC | 100 kΩ /0.32 pF | 23.9 nV/rt(Hz) | AutoProbe2 | No | ±1.25 V | ±16 V | 6:1 |
MX0024A | 20 GHz | RC | 50 kΩ/0.17 pF | 25.0 nV/rt(Hz) | AutoProbe2 | Yes | ±2.5 V | ±16 V | 1:1/4:1/8:1 |
N2801A | 20 GHz | RCRC | 100 kΩ /0.32 pF | 23.9 nV/rt(Hz) | AutoProbe2 | No | ±1.25 V | ±16 V | 6:1 |
N7003A | 20 GHz | RCRC | 100 kΩ /0.32 pF | 33.5 nV/rt(Hz) | AutoProbe2 | Yes | ±2.5 V | ±16 V | 5:1/10:1 |
MX0022A | 16 GHz | RC | 50 kΩ/0.17 pF | 25.0 nV/rt(Hz) | AutoProbe2 | Yes | ±2.5 V | ±16 V | 1:1/4:1/8:1 |
N7002A | 16 GHz | RCRC | 100 kΩ /0.32 pF | 33.5 nV/rt(Hz) | AutoProbe2 | Yes | ±2.5 V | ±16 V | 5:1/10:1 |
MX0021A | 13 GHz | RC | 50 kΩ/0.17 pF | 25.0 nV/rt(Hz) | AutoProbe2 | Yes | ±2.5 V | ±16 V | 1:1/4:1/8:1 |
N7001A | 13 GHz | RCRC | 100 kΩ /0.32 pF | 33.5 nV/rt(Hz) | AutoProbe2 | Yes | ±2.5 V | ±16 V | 5:1/10:1 |
N2832A | 13 GHz | RCRC | 100 kΩ /0.32 pF | 33.5 nV/rt(Hz) | AutoProbe1 | Yes | ±2.5 V | ±16 V | 5:1/10:1 |
1169B | 13 GHz | RC | 50 kΩ /0.21 pF | 25.0 nV/rt(Hz) | AutoProbe1 | No | ±1.65 V | ±16 V | 3.45:1 |
MX0020A | 10 GHz | RC | 50 kΩ/0.17 pF | 25.0 nV/rt(Hz) | AutoProbe2 | Yes | ±2.5 V | ±16 V | 1:1/4:1/8:1 |
1168B | 10 GHz | RC | 50 kΩ /0.21 pF | 25.0 nV/rt(Hz) | AutoProbe1 | No | ±1.65 V | ±16 V | 3.45:1 |
①. Input Impedance Profile: RCRC architecture is the best choice for signals with low source impedance and RC architecture is the best choice for measuring signals that transition to low power modes because it has lower loading. ②. Probe noise listed is the most common setup. Probe noise can vary with multiple factors such as attenuation ratio, probe head, and probe mode. ③. Measure differential, single-ended, and common mode signals. ④. Auto selected based on volts/division (all modes). |
Oscilloscope Compatibility for High-Frequency Differential Active Probes ≥ 10 GHz | |
Probe-to-scope Interface | Compatible Oscilloscopes |
AutoProbe1 | • Infiniium MXR, EXR, S-Series, 9000, and 90000A Series • Infiniium UXR (3.5 mm models), V, Z, Q, and 90000X Series with the use of the N5442A adapter • Infiniium UXR (1 mm & 1.85 mm models) with the cascaded use of the N5442A & N2852A adapters |
AutoProbe2 | • Infiniium UXR (3.5 mm models), V, Z, Q, and 90000X Series • Infiniium UXR (1 mm & 1.85 mm models) with the use of the N2852A adapter • Infiniium N1000A and 86100D DCA-X with the use of the N5477A adapter (only for N2801A/02A/03A) |
High-Voltage Differential Active Probes | |||||||
Model | Bandwidth | Input Range | Diff Input Impedance | Attenuation Ratio | Prob-to-scope Interface | Power Source | Oscilloscope Termination |
DP0010A | 250 MHz | ±42 V | 1.7 MΩ/0.9 pF | 17:1/85:1 | AutoProbe1 | Oscilloscope | 50 Ω |
DP0011A | 500 MHz | ±42 V | 1.7 MΩ/0.9 pF | 17:1/85:1 | AutoProbe1 | Oscilloscope | 50 Ω |
DP0012A | 1.0 GHz | ±42 V | 1.7 MΩ/0.9 pF | 17:1/85:1 | AutoProbe1 | Oscilloscope | 50 Ω |
DP0013A | 1.7 GHz | ±42 V | 1.7 MΩ/0.9 pF | 17:1/85:1 | AutoProbe1 | Oscilloscope | 50 Ω |
N2805A | 200 MHz | ±100 V | 4 MΩ/4.0 pF | 50:1 | AutoProbe1 | Oscilloscope | 50 Ω |
N2804A | 300 MHz | ±300 V | 8 MΩ/10 pF | 100:1 | AutoProbe1 | Oscilloscope | 50 Ω |
N2790A | 100 MHz | ±1400 V | 1 MΩ/3.5 pF | 50:1/500:1 | AutoProbe1 | Oscilloscope | 1 MΩ |
DP0001A | 400 MHz | ±2000 V | 10 MΩ/2.0 pF | 50:1/100:1/250:1/500:1 | AutoProbe1 | Oscilloscope | 50 Ω |
Oscilloscope Compatibility for High-Voltage Differential Active Probes | ||
Probe-to-scope Interface | Oscilloscope Termination | Compatible Oscilloscopes |
BNC | 1 MΩ | • InfiniiVision 1000, 2000, 3000A, 3000T, 4000, and 6000 X-Series • Infiniium EXR, MXR, S-Series, 9000 Series • Any vendor’s oscilloscope with a BNC input connection and a 1 MΩ input impedance termination |
BNC | 50 Ω | • InfiniiVision 3000A, 3000T, 4000, and 6000 X-Series • Infiniium EXR, MXR, S-Series, 9000 and 90000A Series • Any vendor’s oscilloscope with a BNC input connection and a 50 Ω input impedance termination |
AutoProbe1① | 50 Ω | • InfiniiVision 3000A①, 3000T, 4000, and 6000 X-Series • Infiniium EXR, MXR, S-Series, 9000 and 90000A Series • Infiniium UXR (3.5 mm models), V, Z, Q, and 90000X Series with the use of the N5442A adapter • Infiniium UXR (1 mm & 1.85 mm models) with the cascaded use of the N5442A & N2852A adapters |
①. DP0001A is not compatible with the InfiniiVision 3000A X-Series oscilloscopes. AutoProbe1 Interface Keysight’s AutoProbe1 interface provides the following: • DC voltage to power active probe circuitry • Automatic detection of probe attenuation • Automatic control of selectable probe attenuation on some probes • Probe DC offset on many probes |
Single-Ended Active Probes | |||||||
Model | Bandwidth | Input Range | Probe Offset | Input Impedance | Attenuation Ratio | Probe-to-scope Interface | Notes |
N2795A | 1 GHz | ±8 V | ±8 V | 1 MΩ/1.0 pF | 10:1 | AutoProbe1 | |
N2797A | 1.5 GHz | ±8 V | ±12 V | 1 MΩ/1.0 pF | 10:1 | AutoProbe1 | Extreme Temp. (-40 to +85° C), 2 meter long cable |
N2796A | 2 GHz | ±8 V | ±12 V | 1 MΩ/1.0 pF | 10:1 | AutoProbe1 | |
1130B① | 1.5 GHz | ±2.5 V | ±12 V | 25 kΩ/0.44 pF | 10:1 | AutoProbe1 | |
1131B① | 3.5 GHz | ±2.5 V | ±12 V | 25 kΩ/0.44 pF | 10:1 | AutoProbe1 | |
1132B① | 5.0 GHz | ±2.5 V | ±12 V | 25 kΩ/0.44 pF | 10:1 | AutoProbe1 | |
1134B① | 7.0 GHz | ±2.5 V | ±12 V | 25 kΩ/0.44 pF | 10:1 | AutoProbe1 | |
①. Single-ended and differential probe. Requires probe head sold separately. |
Oscilloscope Compatibility for Single-Ended Active Probes | |
Probe-to-scope Interface | Compatible Oscilloscopes |
AutoProbe1 | • InfiniiVision 3000A, 3000T, 4000, and 6000 X-Series • Infiniium EXR, MXR, S-Series, 9000, and 90000A Series • Infiniium UXR (3.5 mm models), V, Z, Q, and 90000X Series with the N5442A adapter • Infiniium UXR (1 mm & 1.85 mm models) with the cascaded use of the N5442A & N2852A adapters (only for N2795A/96A/97A, not for 1130B/31B/32B/34B) |
AutoProbe1 Interface Keysight’s AutoProbe1 interface provides the following: • DC voltage to power active probe circuitry • Automatic detection of probe attenuation • Automatic control of selectable probe attenuation on some probes • Probe DC offset on many probes |
Power Rail Probes | ||||||
Model | Bandwidth | Input Range | Probe Offset | Input Impedance | Attenuation Ratio | Probe-to-scope Interface |
N7020A | 2 GHz | ±850 mV① | ±24 V | 50 kΩ | 1.1:1 | AutoProbe1 |
N7024A | 6 GHz | ±600 mV① | ±15 V | 50 kΩ | 1.3:1 | AutoProbe1 |
①. Measurement range about offset level. |
Oscilloscope Compatibility for Power Rail Probes | |
Model | Compatible Oscilloscopes |
N7020A | • InfiniiVision 3000A, 3000T, 4000, and 6000 X-Series oscilloscopes. • Infiniium EXR, MXR, S-Series, and 9000 Series oscilloscopes. |
N7024A | • Infiniium EXR, MXR, S-Series, 9000 Series, and 90000A Series oscilloscopes. • Infiniium UXR-Series, V-Series, Z-Series, 90000Q Series, and 90000X Series with the use of the N5442A adapter. |
AutoProbe1 Interface Keysight’s AutoProbe1 interface provides the following: • DC voltage to power active probe circuitry • Automatic detection of probe attenuation • Automatic control of selectable probe attenuation on some probes • Probe DC offset on many probes |
AC/DC Hall-Effect (Clamp-On) Current Probes | ||||||
Model | Bandwidth | Max Current | Conversion Factor (Attenuation) | Min Scope Vertical Scale | Probe-to-Scope Interface | Power Source |
N7026A | 150 MHz | 40 A-Pk①, 30 A-RMS① | 1 V/A (1:1), 0.2 V/A (5:1)② | 1 mA/div | AutoProbe1 | Oscilloscope |
N2893A | 100 MHz | 30 A-Pk③, 24 A-RMS③ | 0.1 V/A (10:1) | 10 mA/div | AutoProbe1 | Oscilloscope |
N2783B | 100 MHz | 50 A-Pk, 30 A-RMS | 0.1 V/A (10:1) | 10 mA/div | BNC | N2779A |
1147B | 50 MHz | 30 A-Pk③, 24 A-RMS③ | 0.1 V/A (10:1) | 10 mA/div | AutoProbe1 | Oscilloscope |
N2782B | 50 MHz | 50 A-Pk, 30 A-RMS | 0.1 V/A (10:1) | 10 mA/div | BNC | N2779A |
N2781B | 10 MHz | 300 A-Pk, 150 A-RMS | 0.01 V/A (100:1) | 100 mA/div | BNC | N2779A |
N2780B | 2 MHz | 700 A-Pk, 500 A-RMS | 0.01 V/A (100:1) | 100 mA/div | BNC | N2779A |
1146B | 100 kHz | 100 A-Pk, 100 A-RMS | 0.1 V/A (10:1), 0.01 V/A (100:1)④ | 10 mA/div | BNC | 9 V Battery |
AC-Only Rogowski Current Probes | |||||
Model | Bandwidth | Max Current | Conversion Factor (Attenuation) | Probe-to-Scope Interface | Power Source |
N7042A | 9.2 Hz- 30 MHz | 300 A-Pk | 0.02 V/A (50:1) | BNC | AC power adapter or 4x AA batteries |
N7041A | 12 Hz - 30 MHz | 600 A-Pk | 0.01 V/A (100:1) | BNC | AC power adapter or 4x AA batteries |
N7040A | 3 Hz - 23 MHz | 3000 A-Pk | 0.002 V/A (500:1) | BNC | AC power adapter or 4x AA batteries |
High-Sensitivity AC/DC R-Shunt Current Probes | |||||||
Model | Bandwidth | Current Range⑤ | Gain | Channels | Probe Heads (Standard) | Probe-to-Scope Interface | Power Source |
N2820A | Zoom-out: 3 MHz Zoom-in: 500 kHz |
Zoom-out: 5 A Zoom-in: 50 µ A |
Zoom-out: 1.97 Zoom-in: 300 |
2 | 20 mΩ, 100 mΩ, User-defined | AutoProbe1 | Oscilloscope |
N2821A | Zoom-out: 3 MHz Zoom-in: 500 kHz |
Zoom-out: 5 A Zoom-in: 50 µ A |
Zoom-out: 1.97 Zoom-in: 300 |
1 | 20 mΩ, 100 mΩ, User-defined | AutoProbe1 | Oscilloscope |
①. When using a power adapter booster (standard). 15 A-Pk, 5 V-RMS without oscilloscope-provided power only. An MXR/EXR enables max current range without using the power adapter. ②. Auto-selected based on Amps/division setting. ③. The maximum number of current probes supported by InfiniiVision oscilloscopes is limited depending on the oscilloscope. Infiniium oscilloscopes have no limitations. ④. Manually selectable. ⑤. A wider input range is possible when using the user-defined head and Rsense. |
Oscilloscope Compatibility for Current Probes | |
Probe-to-scope Interface | Compatible Oscilloscopes |
BNC | • InfiniiVision 1000, 2000, 3000A, 3000T, 4000, and 6000 X-Series • Infiniium EXR, MXR, S-Series, 9000, and 90000A Series • Any vendor’s oscilloscope with a BNC input connection and a 1 MΩ input impedance termination |
AutoProbe1 | • InfiniiVision 3000A, 3000T, 4000, and 6000 X-Series • Infiniium EXR, MXR, S-Series, and 9000 and 90000A Series • Infiniium UXR (3.5 mm models), V, Z, Q, and 90000X Series with the use of the N5449A adapter • Infiniium UXR (1 mm & 1.85 mm models) with the cascaded use of the N5449A & N2852A adapters (only for 1147B and N2893A, not for N7026A, N2820A/21A) |
AutoProbe1 Interface Keysight’s AutoProbe1 interface provides the following: • DC voltage to power active probe circuitry • Automatic detection of probe attenuation • Automatic control of selectable probe attenuation on some probes • Probe DC offset on many probes |
Optical Probes | |||||||
Model | Bandwidth | Inputs | Input Connector Type | Wavelength Range | Required Infiniium Baseline Software | Output Connector Type | Compatible Oscilloscopes |
N7004A | 33 GHz | Single-mode & Multi-mode | FC/PC to 50/125 um fiber | 750 nm to 1650 nm | Version 05.70 or higher | 2.92 mm female | UXR (3.5 mm models), V, Z, Q, and 90000X |
N7005A | 60 GHz | Single-mode | FC/PC to 9/125 um fiber | 1250 nm to 1600 nm | Version 10.25 or higher | 1.85 male | UXR (1 mm & 1.85 mm models) |
제 목 | 파일 다운로드 |
[동영상] 오실로스코프에 대한 심층분석 시리즈 Lesson 18 | AVI |
[동영상] 오실로스코프에 대한 심층분석 시리즈 Lesson 17 | AVI |
[동영상] 오실로스코프에 대한 심층분석 시리즈 Lesson 16 | AVI |
[동영상] 오실로스코프에 대한 심층분석 시리즈 Lesson 15 | AVI |
[동영상] 오실로스코프에 대한 심층분석 시리즈 Lesson 14 | AVI |
[동영상] 오실로스코프에 대한 심층분석 시리즈 Lesson 13 | AVI |
[동영상] 오실로스코프에 대한 심층분석 시리즈 Lesson 12 | AVI |
[동영상] 오실로스코프에 대한 심층분석 시리즈 Lesson 11 | AVI |
[동영상] 오실로스코프에 대한 심층분석 시리즈 Lesson 10 | AVI |
[동영상] 오실로스코프에 대한 심층분석 시리즈 Lesson 9 | AVI |
[동영상] 오실로스코프에 대한 심층분석 시리즈 Lesson 8 | AVI |
[동영상] 오실로스코프에 대한 심층분석 시리즈 Lesson 7 | AVI |
[동영상] 오실로스코프에 대한 심층분석 시리즈 Lesson 6 | AVI |
[동영상] 오실로스코프에 대한 심층분석 시리즈 Lesson 5 | AVI |
[동영상] 오실로스코프에 대한 심층분석 시리즈 Lesson 4 | AVI |
[동영상] 오실로스코프에 대한 심층분석 시리즈 Lesson 3 | AVI |
[동영상] 오실로스코프에 대한 심층분석 시리즈 Lesson 2 | AVI |
[동영상] 오실로스코프에 대한 심층분석 시리즈 Lesson 1 | AVI |
[교육 동영상] Probe Attenuation | AVI |
[교육 동영상] Probe Compensation | AVI |
[교육 동영상] Single ended vs Differential oscilloscope probes | AVI |
[교육 동영상] Active vs Passive oscilloscope probes | AVI |
[교육 동영상] How to measure current with an oscilloscope | AVI |
[교육 동영상] Effects of oscilloscope probe loading | AVI |
[교육자료] 오실로스코프의 기초 | |
[동영상] Jitter 분석 | AVI |
[동영상] Jitter 기본과 측정 | AVI |
[동영상] InfiniiSim (Embedding) | AVI |
[동영상] InfiniiSim (De-Embedding) | AVI |
[동영상] Eye Diagram 측정과 분석 | AVI |
[동영상] Oscilloscope Basic - Sample Rate | AVI |
[동영상] Oscilloscope Basic - Memory depth | AVI |
[동영상] Oscilloscope Basic - Bandwidth | AVI |
[동영상] Oscilloscope Basic - Probe | AVI |
타사 제품과 차별화 되어 있는 새로운 키사이트의 BenchVue S/W 시스템 | |
오실로스코프를 이용한 RF 분석 | |
[선택 가이드] 키사이트 Active Probe | |
[선택 가이드] 키사이트 Current Probe | |
[선택 가이드] 키사이트 High Voltage Probe | |
[선택 가이드] 키사이트 Passive Probe | |
BenchVue 소프트웨어 | AVI |
IO Libraries Suite Downloads | EXE |
[제품사양서] Keysight Oscilloscope Selection Guide | |
[제품사양서] 1157~8A Active Probe | |
[제품사양서] N287xA Series Passive Probes | |
[제품사양서] N2750~2A Differential Active Probe | |
[제품사양서] N2790~1A, N2891A High voltage Differential Probes | |
[제품사양서] N2792~3A Differential Probe | |
[제품사양서] N2795~6A Active Probes | |
[제품사양서] N2862B,N2863B,N2889A,N2890A Passive Probes | |
[제품사양서] InfiniiVision X-Series Probes&acc |